Stödda enheter
Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
---|---|---|---|
MIC 600TL-X | ❌ | ✅ | |
MIC 750TL-X | ✅ | ||
MIC 1000TL-X | |||
MIC 1500TL-X | |||
MIC 2000TL-X | |||
MIC 2500TL-X | |||
MIC 3000TL-X | |||
MIC 3300TL-X |

Kablage
RS485
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
RS485 A1 | RS485 A | RS485_POS | RS485 A | TX+ |
RS485 B1 | RS485 B | RS485_NEG | RS485 B | TX- |
N/A | RS GND | GND | Not available | G |
Konfiguration
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Som standard är växelriktaren inställd på adress 1. Detta kan ändras via inställningsmenyn för växelriktaren. Detta är bara nödvändigt om flera enheter är anslutna till RS485-kommunikationsbussen.
Du kan ändra adressen för växelriktaren via beröringskontrollen. Det fungerar enligt följande:
Beröringskontroll | Påverkan |
---|---|
Tryck en gång | Ändra visning eller nummer + 1 |
Tryck två gånger | Gå in eller bekräfta |
Tryck tre gånger | Föregående meny |
Håll ned i 5 sekunder |
|
Ändra adressen genom att gå till menyn "Ställ in Comaddr" som visas i bilden till vänster eller ovan. Sätt adressen till ett unikt värde. Se kapitel 7 i växelriktarens manual för mer information.